0.0005° resolution and 20 Hz low-frequency response give condition-monitoring systems a real-time picture of tower attitude, sway amplitude and structural resonance
Ruicom today introduced the WDS826FL dynamic inclinometer, a dual-axis dynamic tilt sensor designed specifically for wind turbine tower sway monitoring. Together with the GKP3 low-frequency vibration sensor, it is designed to give condition-monitoring systems a continuous picture of tower attitude, sway amplitude and structural resonance — so developing issues can be identified long before they become serious.
Why wind towers need dedicated low-frequency sensing
A 100-metre tower is a flexible structure that is rarely completely still. Wind turbine towers oscillate continually under rotor thrust, wind gusts and blade imbalance, and these signals generally sit below 20 Hz — a band where conventional tilt switches and vibration switches tend to be less effective. Dedicated low-frequency sensors turn this hard-to-capture information into earlier indications of yaw misalignment, foundation softening and structural fatigue.
From slow sway to structural resonance
Key specifications — WDS826FL
With excellent low-frequency response, full-temperature-range factory calibration and long-term stability testing, the WDS826FL provides wind turbine operators with a reliable foundation reference for smarter, condition-based maintenance.
0.0005° resolution and 20 Hz low-frequency response give condition-monitoring systems a real-time picture of tower attitude, sway amplitude and structural resonance
Ruicom today introduced the WDS826FL dynamic inclinometer, a dual-axis dynamic tilt sensor designed specifically for wind turbine tower sway monitoring. Together with the GKP3 low-frequency vibration sensor, it is designed to give condition-monitoring systems a continuous picture of tower attitude, sway amplitude and structural resonance — so developing issues can be identified long before they become serious.
Why wind towers need dedicated low-frequency sensing
A 100-metre tower is a flexible structure that is rarely completely still. Wind turbine towers oscillate continually under rotor thrust, wind gusts and blade imbalance, and these signals generally sit below 20 Hz — a band where conventional tilt switches and vibration switches tend to be less effective. Dedicated low-frequency sensors turn this hard-to-capture information into earlier indications of yaw misalignment, foundation softening and structural fatigue.
From slow sway to structural resonance
Key specifications — WDS826FL
With excellent low-frequency response, full-temperature-range factory calibration and long-term stability testing, the WDS826FL provides wind turbine operators with a reliable foundation reference for smarter, condition-based maintenance.